Interior Furring System
Installation & Design Considerations
Maximum furring spacing 24” o.c. Fasten furring to structural wall. Close all joints between foam insulation panels tightly.
For maximum performance, eliminate thermal “shorts” by installing insulation over furring.
The need for and placement of vapor retarders should be determined by the building designer.
Maximum moisture vapor control can be provided by using a 4 mil polyethylene film vapor retarder with a .08 or lower perm rating.
In moderate climate conditions adequate protection can be provided by 2 mil polyethylene film.
Rigid foam insulation must be separated from the building interior. Completely cover insulation with a code-approved thermal barrier.
Architect must supply detail drawing to meet project and building code requirements.
Product Options
FIBERGLAS™ 700 Series Insulation