Interior Furring System

Installation & Design Considerations

  • Maximum furring spacing 24” o.c. Fasten furring to structural wall. Close all joints between foam insulation panels tightly.
  • For maximum performance, eliminate thermal “shorts” by installing insulation over furring.
  • The need for and placement of vapor retarders should be determined by the building designer.
  • Maximum moisture vapor control can be provided by using a 4 mil polyethylene film vapor retarder with a .08 or lower perm rating.
  • In moderate climate conditions adequate protection can be provided by 2 mil polyethylene film.
  • Rigid foam insulation must be separated from the building interior. Completely cover insulation with a code-approved thermal barrier.
  • Architect must supply detail drawing to meet project and building code requirements.