Concrete Deck
Installation & Design Considerations
FOAMULAR® or FIBERGLAS™ insulation board can be installed on the underside of concrete decks with mechanical fasteners, impaling pins or compatible adhesives.
Use, large head mechanical fasteners or minimum 1” washers to prevent fastener head from pulling through insulation.
The need for a vapor retarder should be determined by the designer based on local conditions.
In cold climates vapor retarders should be as continuous as possible. FOAMULAR® 250 has a perm rating less than 1.0. 700 Series facings have perm ratings less than .02.
Utilize Owens Corning BILD-R-TAPE® to seal joints between FOAMULAR® panels. Use a duct closure tape approved under Underwriters Laboratory 181 to seal the vapor retarder facing joints on 700 Series products.
Air circulating or vented from the ceiling plenum to an occupied space must be separated from the polystyrene insulation with a code approved thermal barrier.
Polystyrene insulation must be separated from the building interior with a code approved thermal barrier.
Compliance with local code requirements must be verified.